NFIRS-3 Structure Fire

I1
Structure Type
1 - Enclosed Building
2 - Portable/Mobile Structure
3 - Open Structure
4 - Air-Supported Structure
5 - Tent
6 - Open Platform
7 - Underground Structure
8 - Connective Structure
0 - Other
I2
Building Status
1 - Under Construction
2 - In Normal Use
3 - Idle, Not Routinely Used
4 - Under Major Renovation
5 - Vacant and Secured
6 - Vacant and Unsecured
7 - Being Demolished
0 - Other
U - Undetermined
I3
Building Height

Number of Stories At/Above Grade

Number of Stories Below Grade
I4
Main Floor Size

Total Square Feet
OR
BY
Length (ft) X Width (ft)
J1
Fire Origin
Below Grade
Story of Fire Origin
J3
Number of Stories Damaged By Flame
Number of Stories w/Minor Damage (1-24%)
Number of Stories w/Significant Damage (25-49%)
Number of Stories w/Heavy Damage (50-74%)
Number of Stories w/Extreme Damage (75-100%)

*Count the roof as part of the highest story
K
Type of Material Contributing Most to Flame Spread

K1
Item Contributing Most to Flame Spread

K2
Type of Material Contributing Most To Flame Spread
L1
Presence of Detectors

N - None Present
1 - Present
U - Undetermined
L3
Detector Power Supply

1 - Battery Only
2 - Hardwire Only
3 - Plug-In
4 - Hardwire With Battery
5 - Plug-In With Battery
6 - Mechanical
7 - Multiple Detectors & Power Supplies
0 - Other
U - Undetermined
L5
Detector Effectiveness

1 - Alerted Occupants, Occupants Responded
2 - Alerted Occupants, Occupants Failed to Respond
3 - There Were No Occupants
4 - Failed to Alert Occupants
U - Undetermined
L2
Detector Type

1 - Smoke
2 - Heat
3 - Combination of Smoke and Heat
4 - Sprinkler, Water Flow Detection
5 - More Than One Type Present
0 - Other
U - Undetermined
L4
Detector Operation

1 - Fire Too Small To Activate
2 - Operated
3 - Failed To Operate
U - Undetermined
L6
Detector Failure Reason

1 - Power Failure, Shutoff, or Disconnect
2 - Improper Installation or Placement
3 - Defective
4 - Lack of Maintenance, Dirty
5 - Battery Missing or Disconnected
6 - Battery Discharged or Dead
0 - Other
U - Undetermined