Dräger Alcotest® 9510 Precautionary Checklist

Subject WHITE, MATTHEW

Date 8/4/24

Officer VAVAK

Agency FOLSOM PD

    1. Continuously observe subject for at least fifteen minutes prior to starting the test, during which time the subject must not have ingested alcoholic beverages or other fluids, regurgitated, vomited, eaten, or smoked.
    1. Push the green button near the display to start the test. If the instrument displays "NOT READY" and "WARMING UP", the instrument will proceed to warm up. When the display shows "READY", press the green button again to start the test.
    1. Enter your OPERATOR LAST NAME, OPERATOR FIRST NAME, OPERATOR AGENCY, OPERATOR BADGE #, and AGENCY CASE NUMBER, pressing enter on the keyboard after each field is completed. Review your information then press enter on the keyboard or SAVE on the touch screen to proceed to Step 4.
    1. Enter the subject's information as prompted: SUBJECT LAST NAME, SUBJECT FIRST NAME, SUBJECT MI, SUBJECT DATE OF BIRTH, SUBJECT DRIVER LICENSE NUMBER, SUBJECT DRIVER LICENSE STATE, and SUBJECT OTHER ID NUMBER.
    1. Enter the date first observed in the indicated format. Enter the time first observed in the indicated format. (If 15 minutes has not passed since the first time observed, the instrument will start a countdown timer for the remaining time before the test can be continued.) Review subject information on the summary screen. Press Enter on the keyboard or SAVE on the touch screen to proceed to Step 6.
    1. Ask the subject if they regurgitated during the observation period and enter their response at the "SUBJECT REGURGITATED" prompt. Review regurgitation information on the summary screen. (If "Y" is selected, the instrument will abort the test sequence.) Press Enter on the keyboard to proceed.
    1. Insert new, clean mouthpiece into Breath Inlet Hose.
    1. Instrument will display "PURGING", then "BLANK CHECK", then "AMBIENT AIR CHECK." When instrument displays "PLEASE BLOW", obtain the first breath sample from the subject. Once a sample has been successfully provided, the instrument will display "TWO MINUTE WAIT PERIOD IN PROGRESS." To terminate or indicate a subject refusal at any time, push the "R" button on the screen during this testing procedure.
    1. Once the two minute wait period is completed, the instrument will display "PURGING", then "BLANK CHECK", then "AMBIENT AIR CHECK". When instrument displays "PLEASE BLOW", obtain the second breath sample from the subject.
    1. If the two sets do not agree by 0.02%, the instrument will display "TESTS OUTSIDE TOLERANCE" and repeat Step 9 to obtain a third breath sample from the subject.
    1. Instrument will display "PLEASE WAIT", then print out TWO copies of the results. Sign both copies. Attach the first copy to this checklist for your record. Place the other copy in the designated drop box.
    1. Remove and dispose of the mouthpiece in a sanitary manner and return the breath hose to its original position.

.....

SACRAMENTO COUNTY
LABORATORY OF
FORENSIC SERVICES

.....

ALCOTEST 9510

SERIAL NO. : ARJN-0054
TEST NO. : 01349
DATE : 08/04/2024
START TIME : 00:36
LOCATION : FPD

.....

SUBJECT INFORMATION :

LAST : WHITE
FIRST : MATTHEW
MI : L
DOB : [REDACTED]
DL STATE : [REDACTED]
DL # : [REDACTED]
ID # : -

.....

BREATH ANALYSIS

OBSERVATION START : 00:04
REGURGITATED : NO
DIAGNOSTIC : OK

g/210L TIME
AIR BLANK 0.00 00:39
TEST 1 IR 0.11 00:40
TEST 1 EC PASS 00:40
AIR BLANK 0.00 00:41
AIR BLANK 0.00 00:44
TEST 2 IR 0.11 00:44
TEST 2 EC PASS 00:44
AIR BLANK 0.00 00:45
DIAGNOSTIC OK

.....

OFFICER INFORMATION :

LAST : VAVAK
BADGE # : 272
AGENCY : FOLSOM PD
CASE # : 24-3123

SIGNATURE :

272

.....

Revised 03/2023